HW Interview
BX-04 · Chapter 14 · Bonus: Topics Readers Were Asked

SAR vs sigma-delta ADC, and how to read the datasheet

Level
●● onsite technical
Track
General board
Really testing
Turning datasheet lines into accuracy, noise and timing, and matching the architecture to the signal.

Key number. Reading a 16-bit ADC datasheet that lists 86 dB SINAD, and a sigma-delta with a sinc3 filter at 10 S/s. Result: A '16-bit' part with 86 dB SINAD is a 14-bit converter; a multiplexed sinc3 channel costs 300 ms per switch. Worked out below

The question and its full answer: in the book, page 328: what to say first, the mechanism, the numbers you would say out loud and the follow-ups. This page has the arithmetic: worked numbers, calculators and a longer explanation. About the book →

Worked numbers

The book keeps the mechanism and the numbers you would say out loud. The arithmetic is here, worked from the inputs to the result. Every number in this section is computed from the stated inputs.

A typical case. Reading a 16-bit ADC datasheet that lists 86 dB SINAD, and a sigma-delta with a sinc3 filter at 10 S/s.

  1. Quantization noise of an ideal converter: LSB/√12 rms. A full-scale sine: 2^N·LSB/(2√2) rms.
  2. Their ratio: 2^N·√1.5, which is 6.02·N + 1.76 dB. Ideal 12-bit: 74.0 dB; ideal 16-bit: 98.1 dB.
  3. ENOB from the measured SINAD: (86 − 1.76)/6.02 = 14.0 bits. Two bits are lost to noise and distortion.
  4. Noise-free bits for DC: peak-to-peak noise ≈ 6.6 × rms, so subtract log2(6.6) = 2.7 bits from the rms resolution.
  5. Sinc3 at 10 S/s settles in 3 output periods: 300 ms after a step or channel change.

Result. A '16-bit' part with 86 dB SINAD is a 14-bit converter; a multiplexed sinc3 channel costs 300 ms per switch.

Sanity check. A SAR has no digital filter memory, so it can switch channels every conversion; its driver must settle each charge kick instead.

Calculators for this question

Run your own numbers. Each tool shows its formula and a worked example.

ADC ENOB, SNR and noise budget

Going deeper: SAR vs sigma-delta ADC

The longer explanation the book has no room for: where people go wrong, and how to say it in the room.

Static lines and dynamic lines. DNL and INL describe the transfer curve: DNL is each step's error, INL is the running sum, the bend from a straight line. SNR, SINAD and ENOB describe a sampled sine wave, so they include noise and distortion.

Which architecture. A SAR takes an independent snapshot each conversion: good for multiplexed channels and control loops, as long as the driver settles each sampling kick. A sigma-delta oversamples a coarse quantizer and filters digitally: high resolution for slow signals, but the filter needs several output periods after any step or channel change.

Where people go wrong

Say it in the room: "I'd compare ENOB at my frequency, then INL and offset for accuracy. SAR for muxed or fast loops, sigma-delta for slow precision, with its settling time counted."

Errata

None known. All errata

Questions or corrections

Ask about BX-04

Related

← BX-03 Resistor technologies and their limitsBX-05 Diode types; Zener and avalanche breakdown →