SAR vs sigma-delta ADC, and how to read the datasheet
Key number. Reading a 16-bit ADC datasheet that lists 86 dB SINAD, and a sigma-delta with a sinc3 filter at 10 S/s. Result: A '16-bit' part with 86 dB SINAD is a 14-bit converter; a multiplexed sinc3 channel costs 300 ms per switch. Worked out below
Worked numbers
The book keeps the mechanism and the numbers you would say out loud. The arithmetic is here, worked from the inputs to the result. Every number in this section is computed from the stated inputs.
A typical case. Reading a 16-bit ADC datasheet that lists 86 dB SINAD, and a sigma-delta with a sinc3 filter at 10 S/s.
- Quantization noise of an ideal converter: LSB/√12 rms. A full-scale sine: 2^N·LSB/(2√2) rms.
- Their ratio: 2^N·√1.5, which is 6.02·N + 1.76 dB. Ideal 12-bit: 74.0 dB; ideal 16-bit: 98.1 dB.
- ENOB from the measured SINAD: (86 − 1.76)/6.02 = 14.0 bits. Two bits are lost to noise and distortion.
- Noise-free bits for DC: peak-to-peak noise ≈ 6.6 × rms, so subtract log2(6.6) = 2.7 bits from the rms resolution.
- Sinc3 at 10 S/s settles in 3 output periods: 300 ms after a step or channel change.
Result. A '16-bit' part with 86 dB SINAD is a 14-bit converter; a multiplexed sinc3 channel costs 300 ms per switch.
Sanity check. A SAR has no digital filter memory, so it can switch channels every conversion; its driver must settle each charge kick instead.
Calculators for this question
Run your own numbers. Each tool shows its formula and a worked example.
Going deeper: SAR vs sigma-delta ADC
The longer explanation the book has no room for: where people go wrong, and how to say it in the room.
Static lines and dynamic lines. DNL and INL describe the transfer curve: DNL is each step's error, INL is the running sum, the bend from a straight line. SNR, SINAD and ENOB describe a sampled sine wave, so they include noise and distortion.
Which architecture. A SAR takes an independent snapshot each conversion: good for multiplexed channels and control loops, as long as the driver settles each sampling kick. A sigma-delta oversamples a coarse quantizer and filters digitally: high resolution for slow signals, but the filter needs several output periods after any step or channel change.
Where people go wrong
- Quoting the bits on the label instead of ENOB at the input frequency you care about.
- Multiplexing a sigma-delta every sample and reading the filter's memory of the last channel.
- Reading RMS noise as the DC resolution: peak-to-peak is about 6.6 times larger.
Say it in the room: "I'd compare ENOB at my frequency, then INL and offset for accuracy. SAR for muxed or fast loops, sigma-delta for slow precision, with its settling time counted."
Errata
None known. All errata
Questions or corrections
Related
← BX-03 Resistor technologies and their limitsBX-05 Diode types; Zener and avalanche breakdown →