Resistor technologies: temperature coefficient, voltage coefficient and voltage rating
Key number. A divider that scales 400 V down to 2.5 V and must hold its ratio from 25 °C to −40 °C. Result: Split the top leg, use thin film for the ratio, and check each part's working-voltage rating, not just its power. Worked out below
Worked numbers
The book keeps the mechanism and the numbers you would say out loud. The arithmetic is here, worked from the inputs to the result. Every number in this section is computed from the stated inputs.
A typical case. A divider that scales 400 V down to 2.5 V and must hold its ratio from 25 °C to −40 °C.
- Thick film at ±100 ppm/°C, legs drifting in opposite directions over 65 °C: 2 × 100 ppm × 65 = 1.3% of ratio error.
- Thin film at 0.1% and ±25 ppm/°C: 0.2% from tolerance plus 2 × 25 ppm × 65 = 0.33% from temperature.
- Voltage: the top leg sees 400 V and the bottom 2.5 V, 160 times more, so voltage coefficient does not cancel.
- Working voltage: a 1206 is rated about 200 V. Four 1 MΩ 1206 parts over 25.2 kΩ: 99.4 µA, 99 V and 9.88 mW each, bottom at 2.50 V.
Result. Split the top leg, use thin film for the ratio, and check each part's working-voltage rating, not just its power.
Sanity check. Typical ratings: 0603 75 V and 0.1 W, 0805 150 V and 0.125 W, 1206 200 V and 0.25 W, power derated above 70 °C.
Calculators for this question
Run your own numbers. Each tool shows its formula and a worked example.
Going deeper: resistor temperature coefficient and voltage limits
The longer explanation the book has no room for: where people go wrong, and how to say it in the room.
Three numbers the tolerance does not cover. Temperature coefficient, voltage coefficient and maximum working voltage. Tolerance describes one part at 25 °C and a low test voltage.
By technology. Thick film is cheap and handles pulses, but drifts 100–200 ppm/°C, loses resistance at high voltage and has the most excess noise. Thin film reaches 5–25 ppm/°C and 0.1%. Metal foil reaches about 1 ppm/°C. Wirewound takes power and pulses but is an inductor.
In a divider only mismatch counts. Matched parts on one substrate (a resistor network) track each other far better than two loose parts of the same grade.
Where people go wrong
- Checking only power on a high-voltage divider: a 1206 has a working-voltage limit even at a few mW.
- Expecting voltage coefficient to cancel: the top leg sees almost all the voltage.
- Blaming Johnson noise on the technology: it depends only on R and T; excess noise is what differs.
Say it in the room: "Tolerance is the 25 °C number. Over temperature and voltage, tempco, voltage coefficient and working voltage decide, so I'd split the top leg and use thin film."
Errata
None known. All errata
Questions or corrections
Related
← BX-02 Divider values for an ADC inputBX-04 Reading an ADC datasheet; SAR or sigma-delta →