Zener vs avalanche breakdown, and the diode types around them
Key number. Zener and TVS numbers worth knowing. Result: The load behind a 12 V TVS must survive about 20 V, more with trace inductance. Worked out below
Worked numbers
The book keeps the mechanism and the numbers you would say out loud. The arithmetic is here, worked from the inputs to the result. Every number in this section is computed from the stated inputs.
A typical case. Zener and TVS numbers worth knowing.
- Temperature coefficients: about −2 mV/°C at 3.3 V (tunneling), near zero at 5.1–5.6 V, +2 mV/°C at 6.2 V, +8 mV/°C at 12 V (avalanche).
- A 12 V Zener over 50 °C: 8 mV × 50 = 400 mV, or 3.3%.
- A 6.2 V avalanche Zener (+2 mV/°C) in series with a forward diode (−2 mV/°C) cancels to near zero: the classic reference near 6.9 V.
- A TVS with 12 V standoff: breaks down from 13.3 V and clamps at 19.9 V at 30 A: 19.9 × 30 = 597 W, its 600 W peak rating.
Result. The load behind a 12 V TVS must survive about 20 V, more with trace inductance.
Sanity check. Below about 5 V the knee is soft and leaky, so a precision clamp needs a shunt reference.
Going deeper: Zener vs avalanche breakdown
The longer explanation the book has no room for: where people go wrong, and how to say it in the room.
Two mechanisms, one symbol. With heavy doping the depletion region is thin enough for electrons to tunnel straight through: true Zener breakdown, below about 5 V, soft knee, negative temperature coefficient. With lighter doping the region is too wide to tunnel, and carriers gain enough energy to knock out more carriers: avalanche, above about 6 V, sharp knee, positive coefficient.
Why avalanche rises with temperature. In a hotter lattice carriers collide sooner and gain less energy between collisions, so breakdown needs a higher field.
The family. A PN diode stores minority charge (reverse recovery). A Schottky has no minority storage but leaks more. A TVS is an avalanche diode with a large junction, chosen by standoff voltage and clamp voltage at the surge current.
Where people go wrong
- Using a 3.3 V Zener as a precise clamp: its knee is soft and leaky.
- Picking a TVS by breakdown voltage and forgetting the clamp voltage at the real surge current.
Say it in the room: "Below 5 V it's tunneling with a negative tempco, above 6 V it's avalanche with a positive one, and near 5.6 V they cancel."
Errata
None known. All errata
Questions or corrections
Related
← BX-04 Reading an ADC datasheet; SAR or sigma-deltaBX-06 What twisting a pair does →