HW Interview
Free tool · PCB

PCB Trace Width and Current Calculator

Width sets heat; length sets drop. Enter the current and the rise you allow to get a width, then check the IR drop, which is often the real limit on low-voltage rails.

Chart basis: the classic IPC-2221 (IPC-D-275) curve fit I = k·ΔT^0.44·A^0.725, k = 0.048 outer, 0.024 inner. IPC-2152 replaced those charts with measurements; it found inner traces run about as cool as the old outer curve, and that a nearby plane cools a trace far more than its layer does.

How it works

A trace heats until the I²R power in it equals what it loses to the board and the air. The old IPC charts fit that balance with a power law in current, temperature rise and cross-section, measured on boards without nearby planes. Width follows from the cross-section and the copper thickness. Resistance follows from the same cross-section, and it climbs about 0.39% per °C.

Worked example

2 A, 10 °C rise, 1 oz outer layer: A = 42 mil², width 30.8 mil. The old inner-layer curve asks for about 80 mil; IPC-2152's measurements say the inner trace runs much cooler than that. For 1 inch at 35 °C the resistance is about 17 mΩ, so the drop at 2 A is 34 mV.

Assumptions
Sources

Tool v1.0 · 21 Nov 2026 · formulas checked by automated tests against independent Python values.

The interview questions behind this tool

PCB-08: Trace current and thermal design · PI-03: Why use thick, wide traces?