RC Snubber Calculator: the Half-Frequency Method
Measure first, then size. Read the ring frequency, add a known capacitor until the frequency drops (ideally to half), and the two readings give you the parasitic L and C.
Measure the ring with a ground spring and well over its frequency in bandwidth. If the frequency halves, the added capacitor is exactly 3 × C_par.
How it works
The ring is the loop inductance resonating with the switch's output capacitance. Frequency goes as 1/√C, so adding a known capacitor and measuring the new frequency solves for the unknown C, and then L. A resistor equal to √(L/C) damps the ring; the capacitor in series with it must be larger than C_par so the resistor sees the ring, and it costs C·V²·fsw because it charges and discharges once per switching cycle.
- C_par = C_add / ((f1/f2)² − 1); halving gives C_add / 3
- L_par = 1 / ((2π·f1)² · C_par)
- R ≈ √(L_par / C_par)
- C_snub ≈ 3–4 × C_par
- P = C_snub · V² · fsw (use fsw, not the ring frequency)
Worked example
200 MHz ring, 330 pF drops it to 100 MHz: C_par = 110 pF, L_par = 5.76 nH, R ≈ 7.2 Ω (use 7.5 Ω). With C_snub = 330 pF at 12 V and 500 kHz the loss is 24 mW.
Assumptions
- One dominant LC; real layouts have more, so tune on the board.
- Fix the hot loop first (tighter layout, small input cap at the FETs), then slow the edge, then snub.
- Check the resistor's pulse rating and temperature, and re-check efficiency and EMI after adding it.
Sources
- The half-frequency method: power-supply application notes on switch-node snubber design from the major converter vendors.
Tool v1.0 · 21 Nov 2026 · formulas checked by automated tests against independent Python values.