Junction Temperature and Heatsink Calculator

Every linear part, from an LDO to a current sink, burns the voltage it drops times the current. Enter both and the thermal path to see the junction temperature.

θJA from a datasheet is measured on a JEDEC test board; your copper can be better or worse. With a heatsink, θJC + θCS + θSA replaces θJA.

How it works

Power flows from the junction to the air through thermal resistances in series, and the temperature rise across each is power times resistance, just like current through resistors. Add them, multiply by the power, and add the ambient. Run it backwards to get the most power the path can take, or the heatsink a given power needs.

Worked example

A ±5 V output stage sourcing 50 mA at −2.5 V drops 7.5 V: 0.375 W, plus 50 mW of quiescent power. At 60 °C/W and 60 °C ambient the junction reaches 85.5 °C.

Assumptions
Sources

Tool v1.0 · 21 Nov 2026 · formulas checked by automated tests against independent Python values.