An empty capacitor looks like a short. Enter the supply, the capacitance and the cable to see the uncontrolled spike, then the gentler current and the FET heat of a controlled ramp.

A meter of cable is roughly 1 µH of loop inductance. Ceramic capacitors add almost no resistance, so the ring is lightly damped.

How it works

Plugged in with no control, the cable inductance and the capacitor form a series RLC driven by a step. With little resistance the current peaks near V·√(C/L) and the capacitor overshoots toward twice the supply. A hot-swap controller or eFuse instead ramps the voltage, so the charging current is only C·dV/dt, but its FET then absorbs the same energy the capacitor stores, plus any load current times the voltage across it.

Worked example

24 V into 10 µF through 1 µH: about 76 A for microseconds, and the capacitor rings up to nearly 48 V. A 2 ms ramp draws only 120 mA. An eFuse ramping 2 mF at 12 V over 10 ms draws 2.4 A and dissipates 144 mJ in its FET.

Assumptions
Sources

Tool v1.0 · 21 Nov 2026 · formulas checked by automated tests against independent Python values.

The interview questions behind this tool

PI-05: Inrush when hot-plugging · PW-20: eFuse vs PTC fuse; inrush · PC-10: Two-capacitor paradox