Harness IR Drop and Hold-Up Capacitance Calculator
A low-voltage rail does not survive a long harness. Enter the wire, the load and the window to see the drop, what a capacitor bank would need, and what sending a higher voltage does.
Copper resistance at 20 °C; it is about 20% higher at 70 °C. A twisted pair is about 0.5 µH per meter of loop; separated wires are more. Set 'voltage sent' above the load voltage to model a point-of-load regulator.
How it works
Current flows out and back, so the loop resistance is twice the one-way wire plus the contacts. Its drop eats the load's voltage window directly unless a regulator at the load absorbs it, which also cuts the harness current by the voltage ratio. A capacitor alone can only ride a step if it holds C = ΔI·Δt/ΔV, and the harness inductance resonates with whatever capacitance sits at the load.
- R_loop = 2 · length · Ω/m + contacts
- V_drop = I_harness · R_loop
- I_harness = V_load · I_load / (V_sent · η) with a regulator at the load
- C_hold = ΔI · Δt / ΔV
- f_res = 1 / (2π·√(L_harness · C_load))
Worked example
1.0 V at 3 A over 0.3 m of 26 AWG: 80 mΩ of loop, 0.24 V of drop against a ±30 mV window, eight times too much. Riding a 2 A, 100 µs step on capacitors alone needs 6.7 mF. Sending 12 V and regulating at the load cuts the harness current to 0.28 A.
Assumptions
- Copper at 20 °C, solid-wire resistance per AWG; stranded wire is a few percent higher.
- DC drop only in the drop rows; the step is modelled as a constant current for Δt.
- The harness R and L sit inside the regulator's loop: check stability with them in place.
Sources
- AWG resistance: ASTM B258 wire dimensions with annealed copper resistivity.