Synchronous Buck MOSFET Loss Calculator

The two FETs in a buck lose power for different reasons. Enter the converter and each FET's data to see where the loss goes and why the two are picked differently.

Use Rds(on) at the hot junction temperature, often 1.3–1.5× the 25 °C value. The rise + fall time is set by Qgd and the gate driver's current.

How it works

The high-side FET carries the full current while the full input voltage is across it during each edge, so it loses switching energy every cycle; at low duty cycle it conducts only briefly. The low-side FET switches at nearly zero volts with its body diode already on, so it mostly loses I²R for most of the cycle. Gate charge and dead time cost a fixed energy per cycle, so they scale with frequency.

Worked example

12 V to 1 V at 20 A and 500 kHz: high side 0.27 W conduction + 0.6 W switching, low side 0.73 W, gate 0.1 W, dead time 0.28 W: about 2 W on 20 W out. At 2 MHz the 42 ns on-time would be below a 50 ns minimum.

Assumptions
Sources

Tool v1.0 · 21 Nov 2026 · formulas checked by automated tests against independent Python values.