HW Interview
Free tool · Power

Buck Inductor Calculator: Ripple, Peak Current and Isat

Pick the ripple first, then the inductor follows. Enter the converter and the ripple you want to get L, the currents the part must carry, and the output ripple your capacitor will show.

Use the effective output capacitance at your output voltage, not the label value. 20–40% ripple is the usual starting range.

How it works

In steady state the inductor sees Vin − Vout while the high-side switch is on and −Vout while it is off, and the two volt-second areas cancel. That fixes the duty cycle, and the off-time slope Vout/L times the off-time sets the ripple. The part must carry the peak without saturating and the RMS current without overheating.

Worked example

12 V to 3.3 V at 3 A, 500 kHz, 30% ripple: D = 0.275 and L = 5.32 µH, so use 5.6 µH. The ripple is then 0.854 A, the peak 3.43 A and the RMS 3.01 A, so look for Isat ≥ 4.1 A hot. With 22 µF and 5 mΩ the output ripple is about 14 mV before ESL spikes.

Assumptions
Sources

Tool v1.0 · 21 Nov 2026 · formulas checked by automated tests against independent Python values.

The interview questions behind this tool